Abstract

Cleaning of equipment in the production of medicines is an important requirement of good manufacturing practice (GMP). As a rule, the same process equipment is used for the production of a number of different drugs that may result in cross-contamination. In order to prevent the contamination there is need in efficient cleaning of equipment used with the validation methods for each part of equipment. There is need as well to prove and establish acceptable residual limits of active pharmaceutical ingredients (API) on the surface of the equipment after purification (purity acceptance criteria) based on the therapeutic dose of API, toxicity, volume of series, the surface area of the used equipment.

The aim of this work is the development of the simple and selective polarimetry and HPLC methods for determining residual amounts of glucose in washings from surfaces of pharmaceutical equipment after production of the drug. The object of the research is glucose, which is a part of the drug Regidron, powder for oral solution of 18.9 g per sachet. The swab Alpha® Sampling Swab TX715; membrane filters 0.20 µm; Minisart RC 15 «Sartorius» (Germany) were used. The polarimetric and HPLC methods for determination of glucose residues in washings from surfaces of pharmaceutical equipment after production the Regidron were developed.

The recovery rates of glucose from swabs and pharmaceutical equipment surfaces are more than 90%. The proposed simple and rapid methods are characterized by satisfactory metrological characteristics and can be recommended to determine the residues of glucose in controlling the quality of cleaning pharmaceutical equipment.

References

1. PIC / S document PI006-2. Recommendations for the Validation Master Plan, Installation and Operational Qualification. Non Sterile Process Validation, Cleaning Validation; July 2004.
2. U.S. Food and Drug Administration. Guide to inspections validation of cleaning processes; July 1993
3. Harmonov S.Yu., Nurisalova G.R., Fathulin P. P., Goryunova SM, Problems of cross-contamination in chemical and pharmaceutical production: standardization and unification of requirements // Vestn. Kazan technology. un-that - 2006. - Vol. 6. - P. 294-305.
4. Nassani M. Validation in the Pharmaceutical Industry // J. Validation Technol. - 2005. - V. 11, N 4. - P. 286-297.
5. Fourman G., Mullen M. Determining Cleaning Validation Acceptance Limits for Pharmaceutical Manufacturing Operations // Pharm. Technol - 1993. - V. 17, N 4. - P. 54.
6. McCormick P. Y., Cullen L. F. "Cleaning Validation", in Pharmaceutical Process Validation / Ed. by Berry I. R., Nash R.A. 2nd edition. - New York: Marcel Dekker, Inc., 1993. - P. 319-349.
7. Al-Gharabli S.I. Determination of Glucose Concentration in Aqueous Solution Using the ATR-WT-IR Technique // Sensors. - 2009. - V. 9. - P. 6254-6260.
8. Gerasimenko V. L. Review of methods for determining glucose. - Moscow: Nauka, 2005. - 356 pp.
9. Wan Q., Cote'G. L., Dixon J. B. Dual-Wavelength Polarimetry for Monitoring of Glucose in the Presence of Variable Birefringence // J. Biomed Optics. - 2005 - V. 10, N 2. - P. 24-29.
10. Ampon K., Wan Yunus W. Z., Salleh A. B. A Spectrophotometric method for the determination of glucose with glucose oxidase using titanium (IV) -4- (2'-pyridylazo) resorcinol reagent pertanica // J. Sci. Technol - 1994. - V. 2, N 1. - P. 47-53.
11. ZAITOUN M. A. A Kinetic-Spectrophotometric Method for the Determination of Glucose in Solutions J. J. Analytical Chem. - 2006. - V. 61, N 10. - p. 1010-1014.
12. Odden J. Determination of D-glucose in human blood serum using HPLC-PED // Concordia College J. Analytical Chem. - 2011. - V. 2. - P. 58-66.
13. Rahman N. A. Determination of glucose and fructose from glucose isomerization process by high-performance liquid chromatography with UV detection // Modern Appl. Sci - 2008. - V. 2, N 4. - P. 151-154.
14. Salman M., Alghamdi M. T., Bazaid S. A. Determination of fructose, glucose and sucrose in taf grape using high performance liquid chromatography and analysis of mineral salt // Arch. Appl. Sci Res - 2011. - V. 3, N 6. - P. 488-496.
15. State Pharmacopoeia of Ukraine / State Enterprise "Scientific Expert Pharmacopoeia Center". 1st kind. - Kharkiv: RIREG, 2001. - 556 pp.
Published
2018-09-04
How to Cite
FedosenkoA. А., Scrypynets, Y. V., Leonenko, I. I., Yegorova, A. V., KashutskуyS. N., & Antonovich, V. P. (2018). Determination of the glucose residues on pharmaceutical equipment surfaces by both methods: polarimetry and HPLC. Farmatsevtychnyi Zhurnal, (5), 83-89. https://doi.org/10.32352/0367-3057.5.15.05
Section
Production, quality control, standardization of medicines